Technical Data :
Hybrid Energy Lab-System |
|
Dimensions (B × H × T) |
520 × 1330 × 600 mm |
Weight approx. |
200 kg |
Permissible environmental temperature during |
+5 +35 °C |
Connection standards |
DIN, CGA, BS |
Mains connection |
230 VAC (50 Hz), 115 VAC (60Hz) |
Communication interface |
Ethernet |
Fuel Cell Module |
|
Fuel Cell System |
|
Rated output |
1200 W @ 5 ... 25 °C |
Rated current |
60 ADC max. |
Operating voltage |
18 ... 36 VDC |
Maximum hydrogen consumption |
15 Nl/min |
Hydrogen purity for operation |
min. 4.0 |
Permissible H2 inlet pressure |
1 15 bar |
H2 Flow Meter |
|
Measuring range |
0.83 25 Nl/min |
Measuring accuracy |
± 1.5 % from the end value |
H2 Sensor |
|
Sensor standard range |
0.00 1.00 Vol. % H2 |
Power-Management-Modul |
|
DC Converter with Integrated Load Regulator |
|
Max. output power |
1500 W |
Max. output current |
55 ADC |
Rated output voltage |
24 VDC |
Output voltage range |
21 30 VDC |
Max. input current |
60 ADC |
Input voltage range |
18 36 VDC |
Efficiency |
96 % |
Inverter |
|
Continuous output power |
1500 WAC |
Inlet voltage |
21 30 VDC |
Output voltage |
230 VAC (50 Hz), 115 VAC (60Hz) |
Output signal form pure |
Reiner Sinus (THD < 3 %) |
Efficiency |
91/93 % (110/230 V) |
Electronic Load Module |
|
Max. continuous power |
1200 W |
DC load current |
0 85 ADC |
DC load voltage |
0 80 VDC |
Load resistance |
0.08...30 ΩC |
Battery Module |
|
Battery set 1 |
lead-acid, 24 V, (2 x 12 V), 7,2 Ah |
Battery set 2 |
lead-acid, 24 V, (2 x 12 V), 18 Ah |
Safety elements |
30 A, 80 A |
H2 Storage Module |
|
Hydrogen manometer |
0 25 bar |
Safety elements |
3 x temperature sensors, pressure relief valve, hydrogen safety switch, manometer |
Metal Hydride Canisters |
|
Storage capacity |
3x 600 Nl @ 15 bar, 20°C |
All-in-one PC and System Control Module |
|
All-in-one PC, keyboard, mouse and user software |
|
System control with touchscreen for measured value indication and adjustment |