Product Specifications :
Production rate |
500 NL/h |
1.0785 kg/24h |
|
Hydrogen output purity |
35 bar: ~ 99.90% (Impurities: ~ 1000 ppm H₂O) |
8 bar: > 1500 ppm H₂O |
|
Output pressure |
Up to 35 barg |
Nominal power consumption per Nm³ of H₂ produced (beginning of life) |
4.8 kWh/Nm³ |
Operative power consumption |
2.4 kW |
Stand-by power consumption |
15 W |
Power supply |
AC 200 - 240 V, 50/60 Hz |
Ambient operative temperature range |
5 °C - 45 °C |
Ambient operative humidity range |
Up to 95% Rh, non-condensing |
IP rating |
IP 20 |
Control and monitoring |
Fully automatic with Enapter's EMS, Modbus TCP via Ethernet |
Water consumption |
~ 400 mL/h |
Water input conductivity |
< 20 μS/cm (at 25 °C) |
Water input pressure range |
1 - 4 barg |
Max. input pressure for cooling water |
7 barg |
Recommended cooling water flow (beginning of life) |
Range: 0.5 L/min at max. 30 oC inlet temperature to 7 L/min at max. 46 oC inlet temperature, tap-water quality |
Waste heat recovery (beginning of life) |
Up to 490 W (depending on cooling water inlet temperature and flow rate) |
Weight |
54 kg |
Dimensions |
W: 482 mm x D: 634 mm x H: 307 mm |
Space inside cabinet |
7 U |
Conformity |
CE certified according to the machine directive 2006/42/CE |